![sokkia set 3130r3 total station manual sokkia set 3130r3 total station manual](https://i.ytimg.com/vi/CG0shmZ0-sY/hqdefault.jpg)
- Sokkia set 3130r3 total station manual serial#
- Sokkia set 3130r3 total station manual drivers#
- Sokkia set 3130r3 total station manual driver#
- Sokkia set 3130r3 total station manual manual#
- Sokkia set 3130r3 total station manual software#
Older Bluetooth Drivers that can downgrade the Panasonic bluetooth drivers have been uploaded. The gyroscopic total station GP3130R/3130R3 consists of a specially-adapted.
Sokkia set 3130r3 total station manual manual#
Manual for the SET instrument to be used. This unit is in excellent operating and good cosmetic condition. SOKKIA SET 3110 TOTAL STATION Sokkia Set 3110 is 3” angle accuracy total station. One issue that can arise connecting the Sokkia 530r3 units to the Panasonic FZ-M1 tablets running Windows 8.1 is that the bluetooth in the Sokkia units is relatively old (v1) with the Bluetooth drivers in W81 (v3 or v4). We are leaving it online for teams that continue to use the internal controller.
Sokkia set 3130r3 total station manual serial#
Thus the information below that uses Spectrum Link and Serial D9 to transfer files from the internal Sokkia memory is mostly obsolete.
Sokkia set 3130r3 total station manual software#
The FZ-M1 tablets have software installed that control the Sokkia units and Magnet Field can export data to Shapefile or CSV file formats and these files can be copied to USB or transferred in other ways.
![sokkia set 3130r3 total station manual sokkia set 3130r3 total station manual](https://docplayer.net/docs-images/77/76176132/images/139-0.jpg)
These units are reflectorless and are Bluetooth enabled. In 2015 three were purchased to use as controllers for the three Sokkia 530r3 units. Three Sokkia Reflectorless Total Station EDMs purchased together with a tripod, long prism rod, and a long-distance prism. Left and right will be determined by the Run Remotely setting.Dimensions of Equipment Sokkia in protective case 42 x 23 x 34 cm, 10.35 kg (23 lbs): Tripod and stadia rod in Wilson golf case: 133 x 30 x 37 cm, 14.3 kg (31.5 lbs) The reflector prism and soft case are not included in these measurements. For the Sokkia 110M with Remotocatcher, there are 2 buttons in the joystick screen for RC Search: “RC Left” and “RC Right”. This is distinct from left and right referencing for stakeout which refers to movement of the rod. Run Remotely sets the left and right turning of the gun, referenced from the pole, and not from the instrument. Auto Search before Read finds the prism center exactly before taking a measurement (useful in Set Collection, for example, and in Stakeout). The wide views are 6 times field of view. Search types are Sight (field of view of gun, or 1 degree, 30 minutes or 10 meters at 100 meters), H Wide, V Wide and HV Wide. For reference 6 is approximately 6 degrees per arrow press. Joystick speeds are 1 to 6 (for arrow key response turning gun). The Settings options for the 110M are shown below: Change on the instrument and in SurvCE, Equip, Com Setup. Note that baud rates on the 110M must be set to 9600 in remote mode but are typically set to 1200 baud in direct mode. The motorized features will turn to the appropriate horizontal and vertical angle in most commands when the 110M is set to “Remote” mode. For example, in stakeout, it will turn to the point automatically.
Sokkia set 3130r3 total station manual driver#
This driver is necessary to utilize the motorized features of the 110M. The gun will control prism offset in non-prism modes. Use the instrument to activate reflectorless mode, and in SurvCE, be sure to set target height to zero. Commands would not be accepted, for example, if you were in the “Config” screen. The “On” key is the upper right, which takes you to the “Measure” screen where it is ready to work with SurvCE. Most important, for stakeout, the “2-way” setting will upload the angle to turn, so that you turn to zero to get on target. The advantage of Sokkia emulation is that the Sokkia driver includes a “2-way” setting that will upload configuration settings into the instrument such as units, prism constant and the backsight circle. It also applies to many non-Sokkia instruments which have a Sokkia or “Set” emulation mode, including Nikon, Pentax and Topcon. The driver applies to all current Sokkia total stations, including the 110M when used in manual mode. This option only applies to Sokkia total stations or to total stations such as Nikon which have a “Sokkia emulation” mode. When stakeout is completed, the horizontal angle is set back to the original value. Zero Hz Angle to Target : This option specifies whether or not SurvCE will set the horizontal angle of the total station to zero in the direction towards the stakeout point.Target Offset: Enter the prism offset here.EDM Mode: Available methods are rapid and fine.It is recommended that Nikon instruments be run in Sokkia Set emulation mode, enabling the 2-Way communication. The 2-Way option has the one big advantage of sending the angle to turn into the instrument during stakeout, so that looking at the instrument panel, you “turn to zero” to aim at the target point.
![sokkia set 3130r3 total station manual sokkia set 3130r3 total station manual](https://5.imimg.com/data5/SELLER/Default/2020/10/JE/IM/FR/110042082/sokkia-im-55-total-station-250x250.jpg)
![sokkia set 3130r3 total station manual sokkia set 3130r3 total station manual](https://img.youtube.com/vi/D5hlSV4pkT8/hqdefault.jpg)